HIRDA-Ex Explosion-proof Infrared Thermal Imaging Temperature Detection and Analysis System is an infrared thermal imaging product specially designed for use in gas and dust explosion-proof environments, and the system mainly consists of an infrared thermal imaging module, infrared lenses, an explosion-proof protective cover, an explosion-proof control box, an explosion-proof image algorithm server, and a client software. It has passed the double certification of gas explosion-proof and dust explosion-proof, and the explosion-proof level can be up to Ex db IIC T6 Gb /Ex tb IIIC T80℃ Db, and it can be applied to the Zone 1, Zone 2 with the presence of explosive gases and A21 with the presence of dust explosions, A2 area.

 

Contact Us

Specifications

Infrared movement indicator
Detector type Uncooled focal plane microbolometer
number of

pixels

384x288/640x480
Pixel spacing 12μm
Wavelength

range

8~14μm
Thermal

Sensitivity

(NETD)

≤50mk@30℃
Frame rate 25/50Hz
focal length 8mm、13mm、19mm、25mm、35mm可选
Temperature

measurement

range

Normal temperature range: -20°℃~200°C

Medium temperature range: 50°℃ ~ 800°

High temperature range: 50°C~1600°C

Temperature

measurement

±2℃/±2%
PTZ cover
PTZ protection Explosion proof
Shield level Explosion proof
Explosion-proof

level

Ex d IIC T6 Gb/Ex tD A20 IP68 T80°C
Functions
color palette Multiple color palettes including white hot, black hot, ironred, rainbow and more
other With non-uniform correction function, automaticcorrection after power-on
client software Neutral client software is provided, and various functionalparameters of the thermal imager, such as color palette,alarm threshold, and image parameter configuration, canbe remotely set through the client software.
Protocol support
Protocol support TCP/IP, HTTP , RTP , RTSP , NTP , UPnP , ONVIF, UDP
Environmental requirements
Working temperature -40°C~60°C
Storage temperature -45°C~70°C
Resistant temperature shock 5°c/min(-40°c~60°C)
Physical properties and others
power supply AC220V
Power consumption ≤100W
Communication

interface

RJ45/RS485
Overal

dimensions

498mmx295mmx378mm(LxWxH)
Weight <=25kg

Collapse all parameters

If you want to know how to choose
please contact

+86-153-7751-9674